Sanitary Pressure Transducers with Bar Ranges

PXM409S Series

PXM409S Series Sanitary Pressure Transducer | PXM409S Series

PXM409S Series Sanitary Pressure Transducer

846,73 PXM419S20-001BGV

CE
  • 0 to 100 mV, 0 to 10 Vdc, or 4 to 20 mA Outputs
  • Used for liquid level measurment in tanks and silos
  • High 0.08% Accuracy
  • Solid State Sensor for Long Term Stability
  • Welded Stainless Steel Construction
  • Clean In Place (CIP) with 316 SS wetted parts
  • Now Available with M12 Connector, Order Model PXM459S
  • Shock and Vibration Rated
  • Ruggedized with Secondary Containment System
  • Industrial CE Rating
Pressure Transducers - View related products

Description

Click if you want to know more about sanitary sensors.

3-A approved The PXM409S Sanitary Metric range Series micromachined silicon transducers with 1½ or 2" sanitary fittings are ideal for pressure or level Clean In Place (CIP) applications in food processing, beverage, dairy, or bio/ pharmaceutical applications. They are also rugged enough for most industrial applications requiring a high accuracy CIP transducer. The micromachined silicon sensor provides a very stable reading with exceptional high accuracy of 0.08% and a broad compensated temperature range of -4 to 85°C on most ranges. The modular construction allows for fast delivery of most configurations and fittings. Plus, customized models also can be delivered quickly to suit your exact needs.

COMMON SPECIFICATIONS
Accuracy: ±0.08% Best Straight Line (Linearity, Hysteresis and Repeatability combined) Compound Gauge models calibrated in positive direction only
Calibration: 5-point NIST traceable calibration with zero and span values, calibrated in horizontal direction
Operating Temperature Range: -15 to 115°C (-5 to 240°F)
Compensated Temperature Range:
    ≤350 mb: 4.4 to 60°C (40 to 140°F)
    >350 mb: -4 to 85°C (25 to 185°F)
Temperature Compensation Zero and Span Shift Over Compensated Range:
    ≤2 bar: Zero:1.00%
    Span: 0.70%
    = 350 mb: Zero: 0.80%
    Span: 0.50%
    > 350 mb: Zero: 0.50%
    Span: 0.50%
550H and 880H Barometric Range:
    Zero: 0.90%
    Span: 0.50%
Zero Balance: ±0.5% full scale typical ±1% maximum (for ranges =170 mb ±1% typical ±2% maximum)
Span Setting: ±0.5% full scale typical ±1% maximum (for ranges =170 mb ±1% typical ±2% maximum)
Minimum Isolation Between Case and Output Terminations: 100 M Ω @ 50 Vdc
Pressure Cycles: 1 million, minimum
Long Term Stability (1-Year): ±0.1% full scale typical
Shock: 50 g, 11 mS half sine shock, (under test)
Vibration: ±20 g (under test)
Bandwidth: DC to 1 kHz typical
Response Time: <1 mS
Fill Fluid: NEOBEE M5 Food Grade
Approved to 3A Sanitary Specification 74-03 CE Compliant: Meets industrial emissions and immunity standard IEC61326
Environmental Protection: IP65 or IP67 depending upon electrical termination
Pressure Rating: 1½" and 2" Tri-Grip™ (compatible the Tri-Clamp®)
Fitting: 40 bar using suitable clamp
Over Pressure: 4 x rated pressure to maximum rated flange pressure
Secondary Containment: 6 x rated pressure to a maximum of 138 bar (not in clamp)
Wetted Parts: 316L SS
Weight: 285 g (10 oz)
Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
Sanitary Pressure Transmitters/Transducers with 1½ inch Flange
Gauge Pressure Models with 2 metre Vented Cable termination, IP67
PXM409S15-025HGI
Consult Sales  
Availability: 
 
 
0-25 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-025HG10V
Consult Sales  
Availability: 
 
 
0-25 mbar (hPa) range, 0-10VDC Output, Cable termination
PXM409S15-070HGI
Consult Sales  
Availability: 
 
 
0-70 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-070HG10V
Consult Sales  
Availability: 
 
 
0-70 mbar (hPa) range, 0-10VDC Output, Cable termination
PXM409S15-170HGI
Consult Sales  
Availability: 
 
 
0-170 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-170HG10V
Consult Sales  
Availability: 
 
 
0-170 mbar (hPa) range, 0-10VDC Output, Cable termination
PXM409S15-350HGI
1,014.00
Availability: 7 weeks
 
0-350 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-350HG10V
Consult Sales  
Availability: 
 
 
0-350 mbar (hPa) range, 0-10VDC Output, Cable termination
PXM409S15-001BGI
Consult Sales  
Availability: 
 
 
0-1 bar range, 4-20 mA Output, Cable termination
PXM409S15-001BG10V
Consult Sales  
Availability: 
 
 
0-1 bar range, 0-10VDC Output, Cable termination
PXM409S15-002BGI
Consult Sales  
Availability: 
 
 
0-2 bar range, 4-20 mA Output, Cable termination
PXM409S15-002BG10V
Consult Sales  
Availability: 
 
 
0-2 bar range, 0-10VDC Output, Cable termination
PXM409S15-3.5BGI
930.13
Availability: 1 week
 
0-3.5 bar range, 4-20 mA Output, Cable termination
PXM409S15-3.5BG10V
Consult Sales  
Availability: 
 
 
0-3.5 bar range, 0-10VDC Output, Cable termination
PXM409S15-007BGI
Consult Sales  
Availability: 
 
 
0-7 bar range, 4-20 mA Output, Cable termination
PXM409S15-010BGI
930.13
Availability: 1 week
 
0-10 bar range, 4-20 mA Output, Cable termination
PXM409S15-17.5BGI
Consult Sales  
Availability: 
 
 
0-17.5 bar range, 4-20 mA Output, Cable termination
PXM409S15-035BGI
Consult Sales  
Availability: 
 
 
0-35 bar range, 4-20 mA Output, Cable termination
PXM409S15-040BGI
930.13
Availability: 7 weeks
 
0-40 bar range, 4-20 mA Output, Cable termination
Absolute Pressure Models
PXM409S15-350HAI
Consult Sales  
Availability: 
 
 
0-350 mbar (hPa) absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-001BAI
Consult Sales  
Availability: 
 
 
0-1 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-002BAI
Consult Sales  
Availability: 
 
 
0-2 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-3.5BAI
Consult Sales  
Availability: 
 
 
0-3.5 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-007BAI
Consult Sales  
Availability: 
 
 
0-7 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-010BAI
Consult Sales  
Availability: 
 
 
0-10 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-17.5BAI
Consult Sales  
Availability: 
 
 
0-17.5 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-035BAI
Consult Sales  
Availability: 
 
 
0-35 bar absolute pressure range, 4-20 mA Output, Cable termination
PXM409S15-040BAI
Consult Sales  
Availability: 
 
 
0-40 bar absolute pressure range, 4-20 mA Output, Cable termination
Compound Gauge (Bidirectional) Pressure Models with Vented Cable, IP67
PXM409S15-025HCGI
Consult Sales  
Availability: 
 
 
±25 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-070HCGI
Consult Sales  
Availability: 
 
 
±70 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-170HCGI
Consult Sales  
Availability: 
 
 
±170 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-350HCGI
Consult Sales  
Availability: 
 
 
±350 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-001BCGI
Consult Sales  
Availability: 
 
 
±1 bar range, 4-20 mA Output, Cable termination
Vacuum (Negative Gauge) Pressure Models 0=Ambient Pressure
PXM409S15-025HVI
Consult Sales  
Availability: 
 
 
0 to -25 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-070HVI
Consult Sales  
Availability: 
 
 
0 to -70 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-170HVI
Consult Sales  
Availability: 
 
 
0 to -170 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-350HVI
Consult Sales  
Availability: 
 
 
0 to -350 mbar (hPa) range, 4-20 mA Output, Cable termination
PXM409S15-001BVI
Consult Sales  
Availability: 
 
 
0 to -1 bar (hPa) range, 4-20 mA Output, Cable termination
Barometric Ranges (Absolute Pressure)
PXM409S15-1100HBI
Consult Sales  
Availability: 
 
 
0 to 1100 hPa (mbar) range, 4-20 mA Output, Cable termination
PXM409S15-550HBI
Consult Sales  
Availability: 
 
 
550 to 1100 hPa (mbar) range, 4-20 mA Output, Cable termination
PXM409S15-880HBI
Consult Sales  
Availability: 
 
 
880 to 1100 hPa (mbar) range, 4-20 mA Output, Cable termination
Gauge Pressure Models with M12 Connection, IP67
PXM459S15-17.5BGI
935.30
Availability: 1 week
 
0 to 17.5bar range, 4-20 mA Output, M12 connector
All amounts shown in EUR
Note: Comes complete with 5-point NIST traceable calibration. [*] Select electrical termination, no extra charge. Insert “0” for 2 m (9') vented cable with flying leads. For cable with ½ NPT conduit connector order model PXM409CS, no extra charge. Insert “1” for mini DIN cable (mating connector included). Insert “5” for M12 connector, M12 cables sold separately (see below). Custom configurations also available, see omega.com/pxconfig

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Electrical Termination select from:
PXM409S for 2 m (6 ft) vented cable
PXM409CS for conduit fitting with 2m vented cable
PXM419S for mini DIN
PXM429S for Twist-Lock connector
PXM459S for M12 Connector

(2) Process Fitting select from:
15 for 1.5 inch Tri-Grip
20 for 2 inch Tri-Grip (500 psi max)

(3) Range select from:
025H for 0 to 25 mbar
070H for 0 to 70 mbar
170H for 0 to 170 mbar
350H for 0 to 350 mbar
001B for 0 to 1 bar
002B for 0 to 2 bar
3.5B for 0 to 3.5 bar
007B for 0 to 7 bar
010B for 0 to 10 bar
17.5B for 0 to 17.5bar
035B for 0 to 35bar
040B for 0 to 40 bar (1.5 inch Tri-Grip only)
1100 for 0 to 1100 mbar (Barometric Only)
550 for 550 to 1100 mbar (Barometric Only)
880 for 880 to 1100 mbar (Barometric Only)

(4) Pressure Type select from:
G for Gauge pressure
CG for Compound Gauge Pressure (±25 mb to ±1 bar Ranges)
SG for Hermetically Sealed Gauge (PXM429 and Ranges >=7 bar )
A for Absolute pressure (350 mb to 40 bar)
V for Gauge Vacuum (-25mbar to -1bar Ranges)
HB for Barometric Pressure only

(5) Output Type select from:
V for 10 mV/V
5V for 0 to 5 Vdc
10V for 0 to 10 Vdc
I for 4 to 20 mA (zero set to 12 mA for compound gauge ranges)
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.