Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
More information about how a load cell works in this link.
The LC414 is designed for rugged industrial weighing applications. Built-in overload stops and the ability to withstand up to 12.7 mm (0.5") off center loading allows the LC414 to survive in applications when the load cells would not. The all stainless steel construction and sealed connector provides a load cell that can withstand the harsh environments found in most industrial applications. The integral mounting plate with mounting holes makes installation fast and secure.
SPECIFICATIONS Excitation: 10V AC or DC, 15V max Output: 3 mV/V ±0.25% Calibration: 5 points in compression 0%, 50%, 100%, 50%, 0% capacity Linearity: ±0.05% Hysteresis: ±0.05% Repeatability: ±0.02% Max Off Center Load: 12.7 mm (0.5") Change in Output Due to 12.7 mm (0.5") Off Center Loading: 0.5% load Operating Temperature: -18 to 71°C (0 to 150°F) Compensated Temperature: -9.4 to 46°C (15 to 115°F)
Thermal Effects Span: ±0.0014% rdg/°C rated output Zero: ±0.0023% FS/°C rated output Safe Overload: 150% capacity Ultimate Overload: 225% capacity Bridge Resistance: 350 O nominal Protection Level: IP66 Electrical Connection: 6 m (20') Insulation Resistance: 5000 Meg O Span Adjustment: ±2.5% Mating Connector: MS3106F-14S-5S, sold separately Construction: 17-4 pH stainless steel Connector Wiring: A = (-) Output B = (-) Excitation C = Ground D = (+) Output E = (+) Excitation