Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Holland 07077 03815
International+31 (0) 7077 03815

Compact Dual Channel Strip Chart Recorders with Thermocouple and Millivolt Inputs
DISCONTINUED PRODUCT

RD-145 and RD146 Series

Compact Dual Channel Strip Chart Recorders with Thermocouple and Millivolt Inputs 
DISCONTINUED PRODUCT | RD-145 and RD146 Series

See All Models Below

1 year warranty
  • Compact 100 mm (4") Chart Width
  • Type J Thermocouple Input Switchable Between Thermocouple or Millivolt Input
  • Set Thermocouple Zero Without Signal Input
  • 2 Temperature Ranges
  • 2 Voltage Ranges
  • 4 Chart Speeds

Description

The RD145/146 Series Recorders have been discontinued, please review the RD260 Series or the RD100A Series as possible substitutes or consult OMEGA's Temperature Engineering Department for other options.

SPECIFICATIONS

Cold Junction Compensation:Temperature units "J" thermocouple only
Accuracy:±1% span, mV input: ±2% span, thermocouple input (non-linearized)
Chart Drive:Synchronous moter
Chart Paper: 100 mm (4") writing width; 8 meters (25') long; fan fold at 4 cm (1.5"): olive color grid
Chart Speeds: By gear selection - .5, 1, 2, 4cm/min or cm/hr (approximately .2, .4, .8, 1.6 in/min or in/hr). Gear sets supplied
Channels/Pens: 1 or 2
Event Marker:Override event std.
Input Impedance: 2 MΩ typical
Source Impedance:Up to 20 KΩ
Ranges (JC Unit):0 to 100°C and 0 to 500°C. Note: With switch on mV, the mV ranges are 0 to 100 mV and 0 to 500 mV
Ranges (JF Unit): 0 to 250°F and 0 to 1000°F. Note: With switch on mV, the mV ranges are 0 to 100 mV and 0 to 400 mV
Range (mV Unit): 0 to 100 mV and 0 to 400 mV
Suppressed Zero: -20 to 100% (front panel access hole, mini blade); 0 to 500% (rear panel access hole, lower temperature range only), e.g., JC unit can be set to read 500 to 600°C
Elevated Zero: -20 to 100% (rear panel access hole, lower temperature range only), e.g., JC unit can be set to read -100 to 0°C (-100 to 150°F)
Normal Mode Rejection: 16 dB at 60 Hz
Panel Opening: 130 H x 144 W mm (5.12 H x 5.7" W)
Pen Lift: Manual
Power Requirements: 15 Vac ± 10% 60 Hz 1 Pen - 5.5 watts 2 Pens - 7 watts
Response: 0.5 sec full scale
Dimensions: 126 H x 140 W x 165 D mm (4.96 x 5.5 x 6.5")
Mounting:
Optional - Bezel, $53
Optional - Rack Mount, $41

NOTE: Product is Discontinued

Place Order(Specify Model Number)
Part Number/Desc.
Qty
Description
RD-146-JC-HRS
Consult Sales  
Availability: 
 
 
Dual channel, switchable thermocouple/mV inputs, °C range, and cm/Hrs speed
0100-0032
202.38
Availability: 1 week
 
6 pk chart paper, Z-fold 8 meters (25ft) long
0100-0105
73.91
Availability: 1 week
 
6 pk disposable blue pen short nib for channel 1
0100-0109
73.91
Availability: 1 week
 
6 pk disposable blue pen long nib for channel 2
0100-0106
73.21
Availability: 1 week
 
6 pk disposable red pen short nib for channel 1
0100-0110
94.40
Availability: 1 week
 
6 pk disposable red pen long nib for channel 2
0100-0107
73.69
Availability: 11 weeks
 
6 pk disposable black pen short nib for channel 1
0100-0111
73.91
Availability: 11 weeks
 
6 pk disposable black pen long nib for channel 2
0100-0108
73.91
Availability: 1 week
 
6 pk disposable green pen short nib for channel 1
0100-0112
73.91
Availability: 1 week
 
6 pk disposable green pen long nib for channel 2
All amounts shown in EUR
Note: Each unit comes complete with one pen per channel, one roll og paper, and complete operator's manual.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Strip Chart Recorders select from:
145 for 1-channel recorder
146 for Dual channel recorder

(2) Input Types select from:
MV for mV input
J for Switchable thermocouple/mV

(3) °C or °F Ranges select from:
Nothing(leave field blank) for Standard Unit
C for °C range-For J input only
F for °F-For J input only

(4) Speed Types select from:
HRS for cm/Hrs
MIN for cm/min
Note: All combinations may not be valid, check spec sheet for valid part numbers.
We noticed you are from the US. Visit your local site for regional offers and live support.