See All Models Below
Description
Find how a Magnetic Flow Meter.works on this link.Model |
FMG71 |
FMG72 |
FMG73 |
|---|---|---|---|
| Flow Range | 1 to 20 l/min |
2 to 40 l/min |
10 to 200 l/min |
| Accuracy | ±2% of reading |
||
| Signal Output Starts from | Approx. 0.5 l/min |
Approx. 1 l/min |
Approx. 5 l/min |
| Repeatability | 2% |
||
| Liquid Type and Minimum Conductivity | Water and other conductive liquids with minimum conductivity of 50 µS/cm |
||
| Maximum Liquid Temperature | 90 °C |
||
| Ambient Temperature | 5 to 70 °C |
||
| Maximum Pressure | 16 bar (PN 16) |
||
| Diameter | DN 7 |
DN 10 |
DN 20 |
| Process Connection | G1/2A or 1/2" NPT |
G1/2A or 1/2" NPT |
G1A or 1" NPT |
| Flow Indication | Green LED, blinking proportional to flow rate |
||
| Output Signals | |||
| Frequency Output | |||
| Pulse Rate | 855 pulses/litre |
855 pulses/litre |
200 pulses/litre |
| Resolution | 1.2 ml/pulse |
1.2 ml/pulse |
5 ml/pulse |
| Signal Shape | Square wave NPN, internal pull-up resistor 2 kΩ. Pulse duty ratio 50:50 |
||
| Signal Current | Maximum of 20 mA, current limited |
||
| Analogue Output | |||
| Signal and Range | 4 to 20 mA proportional to 0 to 20 l/min |
4 to 20 mA proportional to 0 to 40 l/min |
4 to 20 mA proportional to 0 to 200 l/min |
| Current Limitation | 26 mA approx. |
||
| Maximum Burden | 250 Ω to GND |
||
| General | |||
| Response Time | < 500 mS |
||
| Electrical Connection | M12 x 1 plug |
||
| Power Supply | 24 Vdc ±10% |
||
| Current Consumption | Max. 80 mA |
||
| Electrical Protection | Shortcircuit proof (up to 30 V) and polarity protection (up to -30 V) |
||
| Mechanical Protection Class | IP 65 (NEMA 4X) |
||
| Materials | |||
| Electrodes | Stainless steel 316 TI (1.4571) |
||
| Process Connections | Stainless steel 316 TI (1.4571) |
||
| Measuring Pipe | PEEK-GF30 |
||
| Gasket | EPDM |
||
| Housing | Cast Aluminium |
||