Cookies on the OMEGA websites
We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
CLOSE
Basket  |  Contact  |  Help  | 
Holland 07077 03815
International+31 (0) 7077 03815
Layer N Banner

Temperature and Humidity Controller

CNiTH and DPiTH Series

Temperature and Humidity Controller | CNiTH and DPiTH Series

Temperature and Humidity Controller

667,30 CNiTH-i8DH33-5

5 year warranty
  • Output 1 - Humidity
    Output 2 - Temperature
  • 4 Popular DIN Sizes
  • Ethernet and Serial Communications (optional)
  • User-friendly, Simple to Configure
  • Full Autotune PID Control
  • Choice of Relays, SSR, DC Pulse, Analog Voltage or Current
  • Programmable Ramp and Soak for Humidity and/or Temperature
  • RH/Temperature Probe included
Relative Humidity Measurement Instruments - View related products

Description

The temperature and humidity controllers of the iTH Series are available either as indicators or controllers. The indicators are extremely accurate programmable digital panel meters displaying humidity, temperature, or dew point. The controllers also provide single output control for humidity and temperature and are easily programmed for any control or alarming requirement from simple on-off to full autotune PID control.

The iTH family of meters and controllers are available in four true DIN sizes: the ultra compact 1/32 DIN; the popular midsize 1/16 DIN square model with dual display; the 1/8 DIN vertical, and the 1/8 DIN horizontal with the big bright 21 mm digits.

The iTH Series LED displays can be programmed to change colour between GREEN, AMBER, and RED at any setpoint or alarm point.

The iTH controller models offer a choice of 2 control or alarm outputs in almost any combination: solid state relays (SSR); form “C” SPDT (single pole double throw) relays; pulsed 10 Vdc output for use with an external SSR; or analogue output selectable for control or retransmission of the process value.

The networking and communications options (highly recommended) include direct Ethernet LAN connectivity with an embedded Web server, and serial communications. The C24 serial communications option includes both RS232 and RS485. Protocols include a straight forward ASCII protocol. The C4EIT option includes Ethernet and RS485 ASCII on one device.

The iTH Series meters and controllers are designed for easy integration with popular industrial automation, data acquisition and control programs as well as Microsoft Visual Basic and Excel. Omega provides free configuration software which makes it fast and easy to get up and running. Available for download on the Web.


SPECIFICATIONS
                                                                   
AccuracyRangeRange
+/-4%RH0%-5% RH     ,95%-100% RH
+/-3.5%RH5%-10% RH   ,90%-95% RH
+/-3%RH5%-10% 

Control
Action: Reverse (heat) or direct (cool)
Modes: Time and amplitude proportional control modes; selectable manual or auto PID, proportional, proportional with integral, proportional with derivative with anti-reset windup and ON/OFF
Rate: 0 to 399.9 seconds
Reset: 0 to 3999 seconds
Cycle Time: 1 to 199 seconds; set to 0 for ON/OFF operation
Gain: 0.5 to 100% of span; setpoints 1 or 2
Damping: 0000 to 0008
Soak: 00.00 to 99.59 (HH:MM), or OFF
Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF
Autotune: Operator initiated from front panel for 1 input at a time only

Outputs
There are two physical outputs: Output 1 = RH, Output 2 = Temp
Functions are set up as Outputs (PID or ON/OFF), or Alarms
Ordering output choices:
    Relay: 250 Vac @ 3A or 30 Vdc @ 3A (resistive load); Form C SPDT
    SSR: 20 to 265 Vac @ 0.05 - 0.5A (resistive load); continuous
    DC Pulse: Non-Isolated; 10 Vdc @ 20 mA (used with external SSR)
    analogue Output (Output 1 only): Non-Isolated, control or retransmission 0 to 10 Vdc or 0 to 20 mA;
    500 ohm max, accuracy is ±1% of FS

Control Output 1 and 2
Operation:
    Action: Reverse (heat) or Direct (cool)
    Modes: Time and Amplitude Proportional Control Modes; selectable Manual or Auto PID, Proportional, Proportional with Integral, Proportional with Derivative with Anti-reset Windup and ON/OFF

Alarm 1 and 2 (Programmable)
1) Alarms are used for colour changing sequence of alarm status (visual alarm).
2) Alarm functions are active, in addition to the colour changing functions, if Output 1 & 2 are (menu) disabled.
3) If Alarms are disabled, Output menus (PID or ON/OFF) are active. colour change is still active.
Operation: High/low, above/below, band, latch/unlatch, normally open/normally closed and process/deviation; front panel configurations
-AL Limit Alarm Version: Output 1 & 2 submenus used for PID are eliminated from menu. colour sequence based on alarm setpoints is still available.

Input
Relative Humidity Accuracy/Range: ±2% for 10 to 90%; ±3% for 5 to 10% and 90 to 95% ±4% for 0 to 5% and 95 to 100%
Hysteresis: ±1% RH
Non-linearity: ±3%
Temperature Accuracy/Range*:
±0.5°C for 5° to 45°C (±1°F for 41 to 113°F); up to ±1.5°C for -40° to 5°C and 45° to 124°C (up to ±2.7°F for -40° to 41°F and 113° to 255°F)
Resolution: 0.1%, 12-bit for RH; 0.1°C, 14 bit for temperature
Response Time: 8 seconds, tau 63% for RH; 5 to 30 seconds, tau 63% for temperature
* Note: Extended temperature range is for industrial probe only, the controller’s operating temperature is 0 to 50°C.

Network and Serial Communications (For Options -C24, -C4EIT, -EIT)
Ethernet: Standards compliance IEEE 802.3 10Base-T
Supported Protocols: TCP/IP, ARP
RS232/RS422/RS485: Selectable from menu; both ASCII and MODBUS protocol selectable from menu; programmable 300 to 19.2 K baud; complete programmable setup capability; program to transmit current display, alarm status, min/max, actual measured input value and status
RS485: Addressable from 0 to 199
Connection: Screw terminals

General
A/D Conversion: 12-bit RH and 14-bit temp
    Reading Rate: 2 samples per sec max
    Digital Filter: Programmable
    Decimal Selection: None, 0.1 for temp and humidity
Display: 4-digit, 9-segment LED
    i32, i16D, i8DV: 10.2 mm
    i8: 21 mm
    i8DH: 10.2 mm and 21 mm GREEN, AMBER, and RED programmable colours for process variable, setpoint and temp units
Operating Temperature: 0 to 50°C, 90% RH non-condensing
Protection:
    i32, i16D: IP65 (NEMA 4X) front panel
    i8DH, i8DV: IP23 (NEMA 1) front panel
Power: Refer to ordering guide
No CE compliance above 60 Hz.
Sample Part Numbers Shown Only
Use the Order by Part Number Box (Bottom of Page)to order all other viable configurations!
Part Number/Desc.
Qty
Description
CNITH-I3222-2
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/32 DIN Single Display, Two SSR Outputs, WITH 50 mm Probe on 90 cm cable
CNITH-I3254-5-C24
608,67
Availability: In Stock
 
CONTROLLER,Temperature and RH Input 1/32 DIN Single Display, Analogue output and Pulse, WITH 127 mm Probe on 3 m cable AND Isolated RS-232 and RS-485
DPITH-I16D-5-C24
Consult Sales  
Availability: 
 
 
MONITOR,Temperature and RH Input 1/16 DIN Dual Display, WITH 127 mm Probe on 3 m cable AND Isolated RS-232 and RS-485
CNiTH-i16D33-2
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/16 DIN Dual Display, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 50 mm Probe on 90 cm cable
CNiTH-i16D33-5
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/16 DIN Dual Display, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable
DPiTH-i8DH-5
Consult Sales  
Availability: 
 
 
MONITOR,Temperature and RH Input 1/8 DIN Dual Display Horizontal, with 127 mm Probe on 3 m cable
DPiTH-i8DH-5-EIT
Consult Sales  
Availability: 
 
 
MONITOR,Temperature and RH Input 1/8 DIN Dual Display Horizontal, with 127 mm Probe on 3 m cable PLUS Ethernet with Embedded Web Server
CNiTH-i8DH23-2
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Horizontal, SSR and Form C Relay, WITH 50 mm Probe on 90 cm cable
CNiTH-i8DH33-5
667.30
Availability: 3 weeks
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Horizontal, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable
CNiTH-i8DH33-5-C24
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Horizontal, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable AND Isolated RS-232 and RS-485
CNiTH-i8DH33-5-EIT
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Horizontal, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable PLUS Ethernet with Embedded Web Server
CNiTH-i8DV33-5
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Vertical, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable
CNiTH-i8DV33-5-EIT
Consult Sales  
Availability: 
 
 
CONTROLLER,Temperature and RH Input 1/8 DIN Dual Display Vertical, 2 Relays: Form "C" SPDT 3 A @ 120 Vac, 3 A @ 240 Vac, WITH 127 mm Probe on 3 m cable PLUS Ethernet with Embedded Web Server
Accessories
IP-PCI-10P
36.10
Availability: 7 weeks
 
Porous Polyethylene Industrial Probe Cap, for wet environments, 10 pack. For external industrial probes only
IND-KIT
16.91
Availability: 1 week
 
Replacement Mounting Kit, for external industrial probes

Order By Part Number

Part Number
Qty
Part Number
Qty


All amounts shown in EUR
Note:
1. Analogue output (Option 5) is not available with "-AL" units.
2. "-C4EIT" or "-EIT" option is not available on the 1/32 DIN. Refer to the iServer section for other Ethernet devices that can connect to a CNiTH-i32xx-x-C24.
Units can be powered safely with 24 Vac power, but no certification for CE/UL are claimed.


Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Size select from:
-i8DH for 1/8 DIN Dual Display Horizontal
-i8DV for 1/8 DIN Dual Display Vertical
-i16D for 1/16 DIN Dual Display
-i32 for 1/32 DIN Single Display

(2) Control Outputs select from:
22 for 2 Solid State Relays SSR
23 for SSR and Form C Relay
24 for SSR and Pulse 10V dc
33 for 2 Relays - Form C Relay
42 for Pulsed 10 V dc and SSR
43 for Pulsed 10 V dc and Form C Relay
44 for 2 Pulsed 10 V dc
52 for Analog Output and SSR
53 for Analog output and Relay
54 for Analog output and Pulse

(3) RH/Temp Probe select from:
-2 for 2 in. probe with 3ft cable
-5 for 5 in. probe with 10ft cable

(4) Network Options select from:
Nothing(leave field blank) for no Network Option
-C24 for Isolated RS232 and RS485
-EIT for Ethernet with Embedded Web Server
-C4EIT for Ethernet with Embedded Web Server + Isolated RS485/422

(5) Power Supply select from:
Nothing(leave field blank) for Standard power input 90-240Vac
-DC for Low Power option 12-36 Vdc/24 Vac CNiTH-i32 or 20-36 Vdc/24 Vac CNiTH-i8/i16
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download CNiTH-i8DH & CNiTH-i8DV - Quick Start Manual Humidity + Temp Controller
Download CNiTH-i32 iSeries - Quick Start Manual - Humidity + Temperature Controller
Download CNiTH-16D iSeries - Quick Start Humidity + Temp Controller
Download CNiTH-i8DH, i8DV, i16D, i32 - Temperature + Humidity Controller Manual
Download CNi/CNiS/CNiTH 8,8C,8D,16,16D - -EIT/-C4EIT Option - Embedded Ethernet for iSeries Monitor/Controller
Download DPi/DPiS/DPiTH 8,8C,8D,16 - -EIT/-C4EIT Option - Embedded Ethernet for iSeries Monitor/Controller
We noticed you are from the US. Visit your local site for regional offers and live support.