Cookies on the OMEGA websites We use cookies on this website, these cookies are essential for the website to work correctly.If you continue without changing your settings, we'll assume that you are happy to receive all cookies on this website.To find out more information about these cookies please click here.
Click on this link if you need more information about Pt100.
The M12TX 100Ω RTD sensor
with built-in transmitter can be
programmable by a computer.
The configuration kit required for
programming is M12TX-CONFIG.
This unique probe is ideal for
areas with space limitations where
traditional head connections are
too large to fit. The M12 thread
design offers a secure industrial
connection. The temperature
Transmitter is designed with
mineral insulated cable probe
(MgO) which allows the probe to
have a minimum bend radius of three times the diameter.
Specifications Body: Thermoplastic material Probe Type: Compact mineral insulated cable AISI 316L SS Probe Minimum Bending Radius: Three-times the outer diameter [except the sensing tip which length is 30 mm (1.2")] Connection: M12x1 male in accordance to VDE0627 (output connection) Sensor: RTD Pt100 class A up to 300°C in accordance to IEC751 Range: -50 to 500°C (-58 to 932°F) Tmax. Electronic: 80°C (176°F) Sensor Break Monitoring: Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action Output Signal: 4 to 20 mA Permissible load: 700 @ 24 Vdc [RLo= (Vsupply-8.5)/0.020] Response Time (90%): <50 ms Isolation In-Out: Non-isolated Power Supply: 8.5 to 32 Vdc (polarity protected) Environment Conditions Temperature: -40 to 80°C (-40 to 176°F) for plastic body Relative Humidity: 0 to 100% EMC: In accordance to EN 61326 Degree of Protection: IP65 and IP67 in accordance to IEC60529 Accuracy Transmitter: Maximum of ±0.2°C or ±0.2% of span Sensor: Class A in accordance to IEC751 Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F) Supply Voltage Influence: Negligible Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required) Zero Adjustments: Any value between -50 to 50°C Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)] Sensor Error Compensation: Over 2 points (maximum 1% of span) Factory Setting: 0 to 150°C/sensor break >21 mA (upscale) Response Time: Diameter 3 mm <3.5 second, diameter 6 mm <13 second (test in water to IEC751- time for reaching 63.2% of instantaneous temperature change)
three times the diameter.
† All amounts shown in EUR Note: Comes complete with operator’s manual.
Product Manuals:
Download
M12 Series - Temperature Transmitter with 100 Ohm RTD
Download
M12TX-CONFIG - Configuration Kit for M12TX